By Jun-Dong Chang, Karl Billau

This lawsuits ebook of the Biolox Symposium in Seoul consists of 10 classes and plenary lectures of the most up-tp-date wisdom to be had within the use of Bioceramics and replacement bearings. greater than 50 audio system with world-famous reputations from 12 international locations disguise fifty two themes on contemporary advancements in Bioceramic and substitute bearings in arthroplasty.

Show description

Read or Download Bioceramics and Alternative Bearings in Joint Arthroplasty: 12th BIOLOX® Symposium Seoul, Republic of KoreaSeptember 7 - 8, 2007Proceedings (Ceramics in Orthopaedics) PDF

Similar biophysics books

Biopolymers at Interfaces, Second Edition (Surfactant Science Series)

This re-creation beneficial properties study from approximately 60 of the profession's so much special overseas experts. spotting rising advancements in biopolymer platforms examine with absolutely up to date and extended chapters, the second one version discusses the biopolymer-based multilayer buildings and their program in biosensors, the growth made within the realizing of protein behaviour on the air-water interface, experimental findings in ellipsometry and reflectometry, and up to date advancements referring to protein interfacial behaviour in microfabricated overall research platforms and microarrays.

Recognition Receptors in Biosensors

This e-book provides an important and updated overview of varied reputation receptors, their immobilization, and an summary of floor characterization options. uncommon scientists from key associations world wide have contributed chapters that supply a deep research in their specific matters; even as, each one subject is framed in the context of this built-in strategy.

Extra resources for Bioceramics and Alternative Bearings in Joint Arthroplasty: 12th BIOLOX® Symposium Seoul, Republic of KoreaSeptember 7 - 8, 2007Proceedings (Ceramics in Orthopaedics)

Sample text

However their ceramic processing and test conditions were not clarified and it was also not clear how their x-ray diffraction study would correlate with our Raman Spectroscopy data. The articular surface of AMC ceramic contains agglomerates of both tetragonal and monoclinic zirconia interspersed in a dominant alumina matrix (Fig. 5a). In the sub-surface layers it can be assumed that the alumina matrix constrains the tetragonal zirconia grains, thereby maintaining the desired highstrength core.

Sychterz CJ, Orishimo KF and Engh CA. Sterilization and polyethylene wear: clinical studies to support laboratory data. J Bone Joint Surg Am 86-A: 1017-1022, 2004. 21. Urban JA, Garvin KL, Boese CK, Bryson L, Pedersen DR, Callaghan JJ and Miller RK. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am 83-A: 1688-1694, 2001. 22. Wan Z and Dorr LD. Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant.

Clin Orthop Relat Res, 82-95. 11. Dowd JE, Sychterz CJ, Young AM, Engh CA [2000] Characterization of long-term femoralhead-penetration rates. Association with and prediction of osteolysis. J Bone Joint Surg Am, 82-A, 1102-7. 12. Drees P, Eckardt A, Gay RE, Gay S, Huber LC [2007] Mechanisms of disease: Molecular insights into aseptic loosening of orthopedic implants. Nat Clin Pract Rheumatol, 3, 16571. 13. Dumbleton JH, Manley MT, Edidin AA [2002] A literature review of the association between wear rate and osteolysis in total hip arthroplasty.

Download PDF sample

Download Bioceramics and Alternative Bearings in Joint Arthroplasty: by Jun-Dong Chang, Karl Billau PDF
Rated 4.41 of 5 – based on 5 votes